100-Program does not exist
101-Error reading program
102-Format error
1030-Crash on Plasma Station-1
1031-Crash on Plasma Station-2
1032-Plumbing Box Fault Plasma Station-1
1033-Plumbing Box Fault Plasma Station-2
1034-Low Nitrogen Pressure
1036-Plasma Failed to Fire
103-Internal structure error
1040-Crash on Plasma Station-3
1041-Crash on Plasma Station-4
104-Error during KERF calculation
105-Station reports
1081-Plasma Station %ld Cut Water Pressure
1083-Plasma Station %ld Cut Gas Pressure
1085-Plasma Station %ld Cooling Water Flow
1087-Plasma Station %ld Did Not Fire
1089-Plumbing Box Fault Plasma Station-3
108-Frequency error in axis
1090-Plumbing Box Fault Plasma Station-4
109-Deviation error in axis at speed
110-Cable fault axis
111-Constants not found
112-Error writing
113-Error loading machine interface program
115-Memory overflow
121-System error in standard shapes
122-Constant too long
123-Invalid symbol @
124-Invalid parameter
125-Error in offset
126-Error using #F+
127-Invalid number of signs
128-Smoothing error
129-Axes too short (with #K or #R)
130-Found blank line
131-Error in SKIP function
132-Calculation error
133-Process still running
134-Select process first
135-ALFE reports error
136-Auxiliary function replaced times by
137- key pressed
138-Servicing mode activated
143-Function not admissible during program run. Set initial screen in movement window.
144-End function!
145-Complete program execution
147-148-149-150-Wrong parameter interface
151-Marked section too large
152-Program extent too large
153-Floppy disk <0 | 1> is write protected
154-Floppy disk is full
155-Floppy disk: general error
156-Error reading from
158-Macro definition file not found
159-Syntax error in MACRO definition file
160-Watchdog
161-ASIOB/ATHC-2 error
162-Error control panel
163-Emergency stop chain interrupted
164- # format error
165- # circle error
166- # loss auxiliary function
167- # loss comment
168- # loss geometry
169- # Center or end point greater than 1.3 miles
170-Free axis from reference cam
171- Definition for station not found
172-Error writing
174-Force list is full
175-Timeout
177-Transfer aborted
180-Invalid constants at station . Execute download!
181-Download error at station
182-Power supply interrupted at station
183-Turn on 24 Volt Power
184-No response from station
185-Automatic reference movement not possible, check machine constants
186-Battery RAM checksum error
195-No potentiometer data
200-Too many input variables
201-For reviewed processing - select program again
202- axis reached software limit switch
203-Too many data blocks for program preparation
204-Reference necessary for this situation
205-Set Reference position of main tool first
206-Reference position of main tool already set
207-PPT active
208- in function . System is unstable!!
210-Caution, invalid system configuration!
212-Closed contour
213- # too long
214-Function aborted
215-Error reading cutting data files
216-No cutting data available
217-No valid cutting data stored
218-Excessive nesting of subroutines
220-ALFE - 24-volt supply missing
221-ALFE - 15-volt supply missing
222-ALFE - DMA error
223-Internal logging error A: D: B:
224-IMAJE timing error, status
225-IMAJE does not understand, status
226-Distance between carriagse Y and Y too small. Tangential follower not in basic position.
227-Plate thickness not available in the organizational program
228-Next smaller plate thickness will be used
230- # angle larger than tangential range of unit
231-Directory transfer active
232-Measuring point cannot be reached
233-This function is, at the moment, blocked by another function.
234-Block / offset not found in file
235-Label not found in file
236-Sensor triggered
237-Please wait, MIP being initialized.
238-Memory management error in module
239-Chamfering with variable angles in circular arcs not possible in line , because the arc is larger than a quadrant
241-Please restart control system now!
242-Servicing mode deactivated
243-Y1 carriage must be travelling during plate alignment
246-Syntax error in file %s
250-Error while calibration of sensor
251-Error while calibration of angle
252-Height sensor reports error
253-Order of unknown variable
254-Unknown telegram :
255-Please power on MC
257-Connection-error to MC
258-OC reports synchronization failure with MC
259-MC reports synchronization failure with OC
260-Checksum-error while transmitting constant group
261-Checksum-error while transmitting part program
262-Checksum-error while transmitting cutting data
263-Checksum-error while transmitting
264-Logical error while telegramming
265-Function not available from mainpanel because AHT2 is active
266-AHT2 cannot be connected on OC and MC. Control device constants.