Visit http://www.esabna.com/ for more information about our products.
| Message | Cause of Error | Correction |
| (105) Station <n> reports <n> | Only for machines with ATHC stations. This message only appears if the MIP simulation bit 3 (SYS.KON,5) is set. In that case, all messages from the ATHC boards are displayed (only for stations that are logged on). Station <n> = Station 1 - 16 Reports <n> = Message 0 - 15 with the following meaning: | |
| 0 Voltage error | 0 Inform our after-sales service | |
| 1 Collision | 1 Search for the reason for the collision (e.g. tool ran into workpiece) | |
| 2 External station switched off | 2 Switch external switch to one | |
| 3 Lower limit switch | 3 Raise tool | |
| 4 AFUE error | 4 Ignite flame again | |
| 5 Station constants invalid | 5 Execute a station-constants download | |
| 6 not assigned | 6 none | |
| 7 not assigned | 7 none | |
| 8 not assigned | 8 none | |
| 9 not assigned | 9 none | |
| 10 Guide limit switch tripped | 10 none | |
| 11 Guide limit switch released | 11 none | |
| 12 Upper limit switch tripped | 12 none | |
| 13 Upper limit switch released | 13 none | |
| 14 IHS error/download error | 14 none | |
| 15 IHS confirmation/download confirmation | 15 none |