(105)

Station <n> reports <n>

Only for machines with ATHC stations.

This message only appears if the MIP simulation bit 3 (SYS.KON,5) is set. In that case, all messages from the ATHC boards are displayed (only for stations that are logged on).

Station <n> = Station 1 - 16

Reports <n> = Message 0 - 15 with the following meaning:

 
 

0 Voltage error

0 Inform our after-sales service

 

1 Collision

1 Search for the reason for the collision (e.g. tool ran into workpiece)

 

2 External station switched off

2 Switch external switch to one

 

3 Lower limit switch

3 Raise tool

 

4 AFUE error

4 Ignite flame again

 

5 Station constants invalid

5 Execute a station-constants download

 

6 not assigned

6 none

 

7 not assigned

7 none

 

8 not assigned

8 none

 

9 not assigned

9 none

 

10 Guide limit switch tripped

10 none

 

11 Guide limit switch released

11 none

 

12 Upper limit switch tripped

12 none

 

13 Upper limit switch released

13 none

 

14 IHS error/download error

14 none

 

15 IHS confirmation/download confirmation

15 none