| Message | Cause of Error | Correction |
| (1081) Plasma Station <N> Cut water pressure | Will be found only when using Smart Flow 1 & 2, with PT15, PT19 or PT600 torch. This error is generated if the Cut Water Pressure switch input is in the wrong state. When controlling a PT-19XL torch’s secondary shield, the Cut Water Pressure switch monitors shield air pressure. The CNC watches this input for a change of state, from the off condition to the on condition when the cut water solenoid valve is energized. An error is generated if the input is on when it should be off, or if the input is off when it should be on. If this error message appears, check the following: | 1. Check the cut water pump, it should be adjusted to deliver 120 PSI when pumping. 2. Check the appropriate BITI at the Vision CNC. It should turn on and off with the cut water. |