Home | Contact Us | Service | ESAB North America
 
Pick A Region

Error Numbers

None Program already exists  
100 Program does not exist 3/13/01
101 Error reading program 3/13/01
102 Format error 3/13/01
103 Internal structure error  
104 Error during KERF calculation  
105 Station reports  
108 Frequency error in <n> axis 1/16/01
109 Deviation error in <n> axis at speed <m> 1/16/01
110 Cable fault <n> axis 1/23/01
111 Constants not found  
112 Error writing <n>  
113 Error loading machine interface program  
115 Memory overflow  
116 Drive not ready  
119 Machine still moving 12/11/00
121 System error in standard shapes  
122 Constant too long  
123 Invalid symbol @  
124 Invalid parameter  
125 Error in offset  
126 Error using #F+  
127 Invalid number of signs  
128 Smoothing error  
129 Axes too short (with #K or #R)  
130 Found blank line  
131 Error in SKIP function  
132 Calculation error  
133 Process still running  
134 Select process first  
135 ALFE reports error <n>  
136 Auxiliary function <n> replaced <m> times by <o>  
137 <n> key pressed  
138 Servicing mode activated  
143 Function not admissible during program run. Set initial screen in movement window.  
144 End function!  
145 Complete program execution  
147 148 149 150 Wrong parameter interface <n>  
151 Marked section too large  
152 Program extent too large  4/3/01
153 Floppy disk <0 | 1> is write protected  
154 Floppy disk is full  
155 Floppy disk: general error <m>  2/20/01
156 Error reading from <n>  
158 Macro definition file not found  
159 Syntax error in MACRO definition file  
160 Watchdog 1/30/01
161 ASIOB/ATHC-2 error 1/30/01
162 Error control panel 1/16/01
163 Emergency stop chain interrupted 1/16/01
164 # <n> format error  
165 # <n> circle error  
166 # <n> loss auxiliary function  
167 # <n> loss comment  
168 # <n> loss geometry  
169 # <n> Center or end point greater than 1.3 miles  
170 Free <n> axis from reference cam  
171 Definition for station <n> not found  
172 Error writing <n>  
174 Force list is full  
175 Timeout  
177 Transfer aborted  
180 Invalid constants at station <n>. Execute download!  
181 Download error at station <n>  
182 Power supply interrupted at station <n> 1/16/01
183 Turn on 24 Volt Power  1/30/00
184 No response from station <n> 1/23/01
185 Automatic reference movement not possible, check machine constants  
186 Battery RAM checksum error <n> 1/16/01
187 Incompatible floppy disk format  
195 No potentiometer data  
200 Too many input variables  
201 For renewed processing - select program again  
202 <X Y Y2 P> axis reached software limit switch 1/16/01
203 Too many data blocks for program preparation  
204 Reference necessary for this function  4/3/01
205 Set reference position of main tool first  
206 Reference position of main tool already set  
207 PPT active  
208 <Type of error> in function <Mathematical function>. System is unstable!!  
209 Division by zero at <n>: <m>  
210 Caution, invalid system configuration!   4/3/01
212 Closed contour  
213 # <n> too long  
214 Function aborted  
215 Error reading cutting data files  
216 No cutting data available  
217 No valid cutting data stored  
218 Excessive nesting of subroutines  
220 ALFE - 24-volt supply missing  
221 ALFE - 15-volt supply missing  
222 ALFE - DMA error  
223 Internal logging error A:<n> D:<m> B:<o>  4/3/01
224 IMAJE timing error, status <n>  
225 IMAJE does not understand, status <n>  
226 Distance between carriages Y<n> and Y<m> too small. Tangential follower not in basic position.  
227 Plate thickness <n> not available in the organizational program <m>.  
228 Next smaller plate thickness <n> will be used  
230 # <n> angle larger than tangential range of unit  
231 Directory transfer active  
232 Measuring point cannot be reached  
233 This function is, at the moment, blocked by another function.  
234 Block <n> / offset <m> not found in file <o>  
235 Label <n> not found in file <m>  
236 Sensor triggered  
237 Please wait, MIP being initialized.  
238 Memory management error in module <n>  
239 Chamfering with variable angles in circular arcs not possible in line <n>, because the arc is larger than a quadrant  
241 Please restart control system now!  
242 Servicing mode deactivated  
243 Y1 carriage must be travelling during plate alignment  
246 Syntax error in file %s  
250 Error <n> while calibration of sensor  
251 Error <n> while calibration of angle  
252 Height sensor reports error <n>  
253 Order of unknown variable <n>  
254 Unknown telegram <n> : <m>  
255 Please power on MC  
257 Connection-error to MC  
258 OC reports synchronization failure with MC  
259 MC reports synchronization failure with OC  
260 Checksum-error while transmitting constant group <n>