During automatic plate alignment, the edges of the plate are detected at three points with a sensor. For this measuring procedure, the sensor is lowered into its operating position
This error message is issued if the sensor already detects the plate surface before being lowered into the starting position for the measurement.
Possible causes of the error:
- The sensor is not functioning properly.
- The measuring station's automatic height sensor is set so the station does not retract the sensor far enough from the plate surface in its idle state.